--- title: "Step 1: Power Wiring Connection" slug: "power-in-battery-connections" updated: 2025-07-15T22:28:08Z published: 2025-07-15T22:28:08Z canonical: "knowledgebase.morningstarcorp.com/power-in-battery-connections" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # Step 1: Power Wiring Connection > [!CAUTION] > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Warning(1).png) **WARNING: Shock Hazard** > > Before wiring, verify that all system breakers and disconnect switches are in the OPEN/DISCONNECTED position, and that all fuses are removed from their holders. > > Do not apply power to the ReadyEdge until all wiring has been completed per these instructions. > > > > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Warning(1).png) **AVERTISSEMENT : Risque de choc** > > Avant de faire le câblage, vérifiez que tous les disjoncteurs et interrupteurs de déconnexion du système sont en position OUVERT/DECONNECTÉE, et que tous les fusibles ont été retirés de leurs supports. > > Ne pas appliquer l'alimentation au ReadyEdge jusqu'à ce que tout le câblage soit terminé conformément à ces instructions. > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) ***NOTE****:* ***GROUNDING*** *The power source for the ReadyEdge may be positive grounded, negative grounded, or floating.* > > > > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) **REMARQUE: MISE À LA TERRE** La source d'alimentation pour le ReadyEdge peut être à la terre positive, à la terre négative ou flottante. ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/image(53).png) Power Input Connection location and polarity (termination plug not shown for clarity) 1. Use the included power cable with in-line fuse. **Be sure the fuse has been removed from the holder** before proceeding. 2. Connect the ring-terminal ends of the included power cable to the battery bank. The red wire is positive (+), the black wire is negative (-). 3. Connect the power cable terminal connectors to the ReadyEdge port labeled “Power In, 8-72 vdc (+/-)”. The polarity of the connection is shown in the diagram above. 4. The fuse will be inserted at a later step. Set it aside in a safe place for now.