--- title: "3.10 Network Configuration" slug: "374-liveview-network-configuration" updated: 2025-10-12T15:52:05Z published: 2025-10-12T15:52:05Z canonical: "knowledgebase.morningstarcorp.com/374-liveview-network-configuration" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 3.10 Network Configuration ## Navigating to Network Settings in Morningstar Mobile App Network Settings can be found in the Setup Menu as shown below. ![Navigating to the Network setup page](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/MS_app_setup_to_Network_page(1).png) *Network Settings page in the mobile app* ## Navigating to Network Settings in LiveView > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) ***NOTE****: Installer Access must be enabled and* *Read-Only Mode* *(DIP Switch #1) must be Off/Disabled to change network settings.* Network settings can be found in the *Setup* menu under the *Network* tab as shown below. The current network settings are summarized on the first card as shown below. ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/image(70).png) ## Network Settings Details ### Adjust MODBUS Settings ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/image(71).png) **Modbus ID** - Edit the MODBUS address of the ReadyEdge (default = 1) **Modbus/TCP port** - Change the network port for ReadyEdge MODBUS TCP/IP communication (default port = 502) **Bridge Ethernet Modbus/TCP requests to EIA-485** - Switch ON to enable Modbus bridging. When enabled, MODBUS TCP requests received via Ethernet that are NOT addressed to the ReadyEdge ID (default ID = 1) or its connected products will be “bridged” or transmitted serially onto the EIA-485 network to other MODBUS devices. If a device on the EIA-485 network has the correct ID and responds to the message, the ReadyEdge will “bridge” the response from that device back to the Ethernet network with a properly formed MODBUS TCP response message. > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) ***NOTE****: MODBUS bridging will transmit MODBUS write commands to the EIA-485 network devices even if Read-Only Mode is enabled.* ### Enable/Disable Morningstar Solar Connect Cloud Service ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/image(72).png) ### Edit TCP IP Network Settings ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/image(73).png) ### Modify Time Servers If the ReadyEdge is connected to the Internet, it has the ability to periodically synchronize time and date from a time server. There are three pre-populated, public NTP servers, which users can modify as necessary. The ReadyEdge will attempt to connect to Timer Server 1 first to obtain current time and date. If connection fails, it will attempt to connect to Timer Server 2, and so forth. To enable the use of these time servers, select the “Use Time Servers” option for *Date/Time Source* under the Date & Time tab. ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/image(74).png) ###