3.12 Edit Connected Products Settings

Prev Next

 NOTE: The DIP switches on the Connected Product (ProStar, TriStar, etc) must be set to the “Custom” setting to make use of these adjustable settings.

Editing Connected Product Settings in Morningstar Mobile App

Coming soon…

Editing Connected Product Settings in LiveView

Step 1 - Enable Installer Access

You will need Installer Access to access the Connected Products setup menu in LiveView. Follow the instructions in 3.6 Installer Access.

 NOTE: If an installer password has not yet been created, you will be prompted to enter a new password before proceeding.

Step 2 - Navigate to Connected Products Setup

Navigate to the Connected Products tab under the Setup menu.

Step 3 - Choose a System Voltage Multiplier

The System Nominal Voltage Multiplier does the math for you in the user interface if you prefer to specify charge setpoints at a nominal voltage other than 12-volt.

For example, if the battery manufacturer provides charging setpoints at 48V nominal, you can set the multiplier to 48-volt and enter the settings for Absorption, Float, and Equalize voltage at 48V nominal as specified on the manufacturers spec sheet.

 NOTE: Custom settings are always programmed into the Connected Product as 12 Volt nominal values. The product software multiplies the custom setpoints by 2X or 4X for 24V and 48V operation respectively automatically.

Step 4 - Modify Connected Product Settings

Adjust any settings as necessary and click “Save” in the upper right corner of the screen to save changes.