--- title: "3.1 Adjusting Settings" slug: "41-adjusting-settings" updated: 2026-03-12T18:30:24Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/41-adjusting-settings" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 3.1 Adjusting Settings All settings (excluding factory reset and controlling Ethernet writes) can be configured using Morningstar LiveView web pages. See the main LiveView web page for locations and screens. The configuration sections describe all settings details in terms of LiveView screens, and many settings are also accessible within the Setup-Installer Setup on-board meter menus shown below in Figure 10. > [!WARNING] > ![Warning symbol indicating caution or alertness in various contexts.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/caution ISO.png) CAUTION: > > To effect changes, always use the **Save Button** in upper right corner of the settings area. ### 3.1.1 Using the Meter Display To adjust LCD display appearance, menu-screen behavior, or language, use the Display and Button menu. #### Structure and Navigation *See Figure 10.* Four lighted triangular directional control keys allow movement to reach any desired point on the meter layout. A lit key indicates a valid direction in the layout. The current location is indicated on the display with a column heading, and a bold descriptor. The GenStar MPPT's meter map consists of two main axes. Using the horizontal arrows buttons, the user can scroll right to access more settings, or left to return to the previous screen. Pressing the down arrow button will move to the next lower listing. From a main screen, pressing the up arrow will return to the next main screen up. Scrolling down will continue to move through the subsequent main menu listings. Scrolling to the right, and then down, allows the user to advance to new options in branches and sub-branches. Scrolling to the left will return to the previous menu listing. See the included complete GenStar MPPT Meter Map insert, also available on the Morningstar website GenStar MPPT at: [https://www.morningstarcorp.com/wp-content/uploads/meter-map-genstar-mppt-en.pdf](https://www.morningstarcorp.com/wp-content/uploads/meter-map-genstar-mppt-en.pdf) #### Programmable Soft-key (maps command functions) The GenStar MPPT features a programmable "Soft-key" push-button that can be programmed to turn on and off loads, start manual equalization, or other commands. The Soft-key button is located at the lower left corner of the meter interface (see Figure 2 in Section 1.3). The button can be programmed to control up to two commands - one command with a momentary press, and another with a prolonged (longer than 2 seconds) press. Soft-key commands can be programmed in the Display and Button menu on the Meter Display or the Meter Display Page in LiveView Installer Setup (see Section 3.2.9 Meter Display). #### Accessing Installer Setup > [!NOTE] > ![A hand pointing to the right, indicating direction or emphasis on an object.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/note hand ISO(2).png) NOTE: > > The GenStar MPPT does not use universal default passwords and requires unique credentials to be created on first use. LiveView will prompt for an Administrative password the first time the webpage is loaded. The Lock/Unlock buttons will not be visible until a password is established. > [!NOTE] > ![A hand pointing to the right, indicating direction or emphasis on an object.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/note hand ISO(2).png) NOTE: > > Security related firmware updates will be provided for a minimum of five (5) years from date of manufacture. ![Flowchart illustrating main display settings, commands, and history for device management.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/main local meter display menus.jpg) Figure 10. Main Local Meter Display Menus. ### 3.1.2 Using Morningstar Mobile (Mobile App) Morningstar Mobile is an app available for use with Android or iOS devices, and can be downloaded to a mobile device from either the Google Play Store (Android) or the Apple App Store (IOS). ![QR codes for Android and Apple devices for easy app access.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/android_apple.png) **Android** [https://play.google.com/store/apps/details?id=com.morningstar.android](https://play.google.com/store/apps/details?id=com.morningstar.android) **Apple iOS** [https://apps.apple.com/us/app/morningstar-mobile/id163816.4.491](https://apps.apple.com/us/app/morningstar-mobile/id1638164491) Bluetooth® must be enabled in the Network\ Modbus setup menu to use Morningstar Mobile. The user must have access to the GenStar meter display to pair and connect to the mobile app. The app will prompt the user to verify a 6 digit pin on both the app and on the GenStar meter display during pairing. The application uses Bluetooth LE to communicate with the GenStar, and replicates most of the Morningstar LiveView webpage (see Section 3.1.3). Morningstar Mobile includes much of the functionality seen in the LiveView sections described below. ### 3.1.3 Using the LiveView UI LiveView is an interface that serves Morningstar application web pages directly from the GenStar MPPT. The web pages closely coincide with the GenStar MPPT meter layout and functions. GenStar cannot be commissioned using LiveView. Commissioning requires use of the unit's meter interface. The various LiveView-local meter categories, and their uses, are summarized in Figure 10. The GenStar MPPT has an RJ-45 Ethernet port for connection to a LAN/WAN. For temporary LiveView setup, a Cat 5 or 6 Ethernet cable can be connected between a PC/laptop and a GenStar MPPT Ethernet port. If the GenStar MPPT was connected to the LAN during installation, LiveView can be accessed via LAN/wireless connection. A DHCP-enabled router will automatically assign an IP address and network settings to the GenStar MPPT. After the original assignment, network settings can be changed using LiveView Setup\Network or Installer Setup\Network page, if desired. Using a Web browser, the GenStar MPPT's LiveView Web pages can be accessed via two methods: 1. Enter the GenStar MPPT's IP address into the Address bar, e.g., [http://192.168.1.253.](http://192.168.1.253/) The IP address can be found in the meter display in Settings\Network. 2. Scan the QR code on the serial label with a mobile device or enter the GenStar MPPT's NetBIOS name [product abbreviation + 8-digit serial no.] into the address bar, e.g., [http://GSMPPT22070007.](http://GSMPPT22070007/) The GenStar product abbreviation is GSMPPT. ### 3.1.4 LiveView Screen | The LiveView Screen shows five real-time cards: | | --- | | **Battery Flow Diagram** | showing Charge, Battery and Load summaries | | **Array Details** | showing array voltage, current, MPPT sweep values, and charge moved, charging cur- rent and charging power | | **Charge Controller Details** | showing battery charging state, net charging current, voltage and heat- sink temperature | | **ReadyBlocks** | showing up to (3) ReadyBlocks: Shunt ratings, Relay assignments, BMS system details | | **Errors** | showing daily and total set faults and alarms | ### 3.1.5 Settings Screen > [!NOTE] > ![A hand pointing to the right, indicating direction or emphasis on an object.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/note hand ISO(2).png) NOTE: > > Security related firmware updates will be provided for a minimum of five (5) years from date of manufacture. | The Settings Screen displays all informational and configured system details. The screen is divided into the following areas: | | --- | | **IDs and versions** | View firmware and hardware versions, serial number, key, user interface version and UI build date | | **Charger** | View battery/bank size and all charging parameters | | **Network** | View all network names, addresses, IDs and time servers | | **Meter Display** | View all screen settings, languages, units and programmed soft-key functions | | **Modes and Profiles** | View operating mode, ESC mode, battery profile, LVD-LVR profile | | **DC Load** | View all low voltage disconnect (LVD) and reconnect thresholds, LVD and SOC disconnect timers, SOC disconnect and reconnect percentages, load current compensation value | | **Solar Inputs** | MPPT, fixed voltage, or percentage of Voc | | **ReadyBlocks** | Check type of block in each of three positions - an indication of, "Empty", is shown if no blocks are installed in a position. | | **External Source Timing Controls** | View settings for Primary Generator Warm-up Time, Primary Generator Cool-down Time, Primary Generator Max. Run-time, Primary Generator Min. Run-time |