--- title: "4.1 TrakStar MPPT Technology" slug: "51-trakstartm-mppt-technology" updated: 2026-03-12T15:40:34Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/51-trakstartm-mppt-technology" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 4.1 TrakStar MPPT Technology The GenStar MPPT utilizes Morningstar's TrakStarTM Maximum Power Point Tracking technology to extract maximum power from the solar module(s). The tracking algorithm is fully automatic and does not require user adjustment. Trakstar technology will track the array maximum power point voltage (Vmp) as it varies with weather conditions, ensuring that maximum power is harvested from the array through the course of the day. **Current Boost:** In many cases, TrakStar MPPT technology will "boost" the solar charge current. For example, a system may have 2 amps of solar current flowing into the GenStar MPPT and five amps of charge current flowing out to the battery. The GenStar MPPT does not create current! Rest assured that the power into the GenStar MPPT is the same as the power out of the GenStar MPPT. Since power is the product of voltage and current (Volts x Amps), the following is true*: 1. Power Into the GenStar MPPT = Power Out of the GenStar MPPT 2. Volts In x Amps In = Volts Out x Amps Out ** assuming 100% efficiency i.e. if no losses in wiring and conversion existed.* If the solar module's Vmp is greater than the battery voltage, it follows that the battery current must be proportionally greater than the solar input current so that input and output power are balanced. The greater the difference between the maximum power voltage and battery voltage, the greater the current boost. Current boost can be substantial in systems where the solar array is of a higher nominal voltage than the battery as described in the next section. **High Voltage Strings and Grid-tie Modules** Another benefit of TrakStar MPPT technology is the ability to charge 12 or 24 volt batteries with solar arrays of higher nominal voltages. A 12 volt battery bank can be charged with a 12, 24, 36 or 48V nominal off-grid solar array. Certain grid-tie solar modules may also be used as long as the solar array open circuit voltage (Voc) rating will not exceed the GenStar MPPT 200V maximum input voltage rating at worst-case (lowest) module temperature. The solar module documentation should provide Voc vs. temperature data. Higher solar input voltage results in lower solar input current for a given input power. High voltage solar input strings allow for smaller gauge solar wiring. This is especially helpful for systems with long wiring runs between the solar array and the GenStar MPPT. **An Advantage Over Traditional Controllers** Traditional controllers connect the solar module directly to the battery when recharging. This requires that the solar module operate in a voltage range that is below the module's Vmp. In a 12V system, for example, the battery voltage may range from 10 - 15 Vdc but the module's Vmp is typically around 17V. Figure 12 shows a typical current vs. voltage output curve for a nominal 12V off-grid module. ![Graphs illustrating current versus voltage and output power for a 12V module.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/nominal 12V solar module.jpg) Figure 12. Nominal 12 Volt Solar Module I-V Curve and Output Power Graph.