--- title: "4.5 LED Indications" slug: "55-led-indications" updated: 2026-03-12T15:49:28Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/55-led-indications" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 4.5 LED Indications The GenStar MPPT meter face (see Figure 2) houses one Charging Status LED (left of screen) and a set of three battery State-of-Charge LEDs (beneath screen - horizontal). **Charging Status LED** The Charging Status LED indicates charging status and any existing solar input error conditions. The Status LED is on when charging during the day and off at night. The Status LED will flash red whenever an error condition(s) exists. Table .4..4 lists the Status LED indications. | **Status LED Color** | **Indication** | **Operating State** | | --- | --- | --- | | None | Off (with heartbeat1) | Night | | Green | On Solid (with heartbeat2) | Charging | | Red | Flashing | Error | | Red | On Solid (with heartbeat2) | Critical Error | *1 Heartbeat indication flickers the Status LED on briefly every 5 seconds 2 Heartbeat indication flickers the Status LED off briefly every 5 seconds* ###### NOTES: 1. R flashing is generally a user addressable fault / error 2. R charging status LED ON with heartbeat blink OFF every 5 secs is a critical fault that generally requires service. See, "Solid Charging Status LED with Self-test (R-Y-G) SOC Faults", in Section 4.6 Faults and Alarms. **SOC LEDs** The Green, Yellow or Red State-of-Charge LEDs are used for general indications and charging indications. **LED Display Key** | G | green | | --- | --- | | Y | yellow | | R | red | | Y - R | yellow and red flashing | | G / Y | Green and Yellow are both lit at the same time | | G / Y - R | Green & Yellow both lit, then red flashing sequentially | | G-Y-R | green, yellow and red flashing sequentially | *Sequencing LED patterns (faults) repeat until the fault is cleared* **General LED Indications** The State of Charge LED's provide the following Start-up and Factory reset indications. | Normal Start-up LED Indication | G for 3 seconds, G-Y-R Flashing, then battery charge status | | --- | --- | | Start-up Bootload Failed LED Indication | G/Y/R for 3 seconds the STOP on Y | | Factory Reset LED Indication | All LED 3 times, then R-Y-G | **SOC LED Charging Indications** The Green, Yellow and Red State-of-Charge LEDs are used to indicate the following charging states. | **State** | **SOC LED Indications** | | --- | --- | | Equalize start request | G / Y / R - G / Y / R - G - G | | Equalize cancel request | G / Y / R - G / Y / R - R - R | | Equalization stage | G flashing (2 per sec) | | Absorption stage | G flashing (1 per sec) | | Float stage | G flashing (1 per 2 secs) | **Battery State-of-Charge (SOC) LED Transitions** During the Bulk Stage, or when the controller is not charging, the Green, Yellow, and Red SOC LEDs will indicate the SOC according to the Battery SOC LED Transition Settings. Battery State-of-Charge (SOC) LED transitions are based on voltage thresholds. When SOC percentage is available from an installed ReadyShunt or ReadyBMS accessory (see Battery State-of-Charge (SOC) Reporting in Section 3.2.7) the SOC LED transitions will be based on SOC percentage. | **Factory Default Battery SOC LED Voltage Thresholds** | | --- | | **Battery SOC LEDs** | **Voltage Threshold** | | Green | battV > 13.3V | | Green / Yellow | 13.0V < battV <= 13.3V | | Yellow | 12.65V < battV <= 13.0V | | Yellow / Red | battV <= 12.65V | | Red | During LVD | Note that voltage threshold State-of-Charge LED displays are only approximate indications of battery charge state, and have variable accuracy during charging and discharging. In addition, the factory default Battery SOC LED indication settings are not appropriate for all battery types and system designs. Therefore, the SOC LED transition settings can be custom programmed to provide a more accurate representation of SOC. The following voltage threshold settings are suggested to better indicate actual SOC. | **Suggested Lead-Acid Battery SOC LED Voltage Threshold Settings** | | --- | | **Battery SOC LEDs** | **Voltage Threshold** | | Green | battV > 13.3V | | Green / Yellow | 13.0V < battV <= 13.3V | | Yellow | 12.5V < battV <= 13.00V | | Yellow / Red | battV <= 12.50V | | Red | During LVD | > [!NOTE] > ![A hand pointing to the right, indicating direction or emphasis on an object.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/note hand ISO(2).png) NOTE: > > Thresholds are more representative of SOC during Bulk Charging. Lower settings can be used to better indicate SOC during periods of battery discharge. | **Suggested Lithium (LFP) Battery LED Voltage Threshold Settings** | | --- | | **Battery SOC LEDs** | **Voltage Threshold** | | Green | battV > 13.4V | | Green / Yellow | 13.25V < battV <= 13.4V | | Yellow | 13.1V < battV <= 13.25V | | Yellow / Red | battV <= 13.1V | | Red | During LVD | **Factory Default Battery SOC LED SOC Percentages - for use with ReadyBMS or ReadyShunt accessory:** | **Battery SOC LEDs** | **Condition** | | --- | --- | | Green | SOC > 80% | | Green / Yellow | 60% < SOC <= 80% | | Yellow | 40% < SOC <= 60% | | Yellow / Red | SOC <= 40% | | Red | LVD or Low SOC Disconnect | **Ethernet Jack Indications** Two (2) small LEDs can be found on the Ethernet RJ-45 jack inside the wiring box. These LEDs indicate the LAN/WAN network link and activity status as follows: | **Condition** | **Green LED** | **Yellow LED** | | --- | --- | --- | | Network Connection OK | ON | OFF | | Network Activity | ON | Blinking | | Error | OFF | ON |