--- title: "4.6 Alarms and Faults" slug: "56-alarms-and-faults" updated: 2026-03-12T15:56:44Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/56-alarms-and-faults" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 4.6 Alarms and Faults Alarms and faults are indicated with LEDs on the unit, and with brief descriptions in LiveView web interface. Alarms are generally informational (see ReadyBlock Alarms below), and faults cause interruption in operation. #### Alarms **Battery Sense Out of Range / Disconnected** (only alarm with LED indications) Charging Status LED: Flashing red. Battery SOC LEDs: R/Y - G/Y sequencing. A battery sense wire is disconnected. Inspect the battery sense connections. This alarm is set when the voltage at the battery sense terminals differs by more than five volts from the voltage at the battery terminals. **Current Limit** The array power exceeds the rating of the controller. This alarm indicates that the GenStar MPPT is limiting battery current to the maximum current rating. **Heatsink Temperature Sensor Open / Shorted** The heatsink temperature sensor is damaged. Contact your Authorized Morningstar Dealer for service. **High Input Voltage Current Limit** The GenStar MPPT will limit the solar input current as the solar array Voc approaches the maximum input voltage rating. The array Voc should never exceed the 200 Volt maximum input voltage - see the array voltage de-rating graph in Appendix. **High Temperature Current Limit** The GenStar MPPT will limit the solar input current if the heatsink temperature exceeds safe limits. Solar charging current will be tapered back (to 0 Amps if needed) to reduce the heatsink temperature. The GenStar MPPT will operate with full-rated current up to +45°C (at full power) and may derate at higher ambient temperatures. Systems with higher array input voltages will have higher internal temperatures resulting in a greater amount of high temperature current-limiting above +45°C. Maximum charging current yield depends on many factors, including sufficient airflow, and good ventilation can greatly reduce the amount of de-rating. If the controller frequently reports this alarm condition, corrective action should be taken to provide better air flow, or to move the controller to a cooler location. **Load Short Circuit** Charging Status LED: Flashing red. Battery SOC LEDs: R/G-Y sequencing. Fully protected against load wiring short-circuits. After two (2) automatic load reconnect attempts (10 seconds between each attempt) the GenStar MPPT will wait, and then automatically reconnect the load, once the short is cleared. **RTS Open** The Remote Temperature Sensor is not connected to the controller. Use of the RTS is recommended for proper battery charging. **Uncalibrated** The controller was not factory calibrated. Contact your Authorized Morningstar Dealer for service. #### READYBLOCK ALARMS A BMS, Shunt or Relay Block can trigger the following alarms on the host which will trigger a disconnection (shutdown) of the charge controller. **BMS Block Removed** If the host is configured to use a battery that requires BMS communication and a BMS block is not connected to the Ready Rail (BlockBus), this alarm will be present until a BMS block is connected. **BMS Lost Communication** If for any reason the ReadyBMS is present and communication with a battery is lost, this alarm will be present until communication is reestablished. **BMS Sense Error** BMS sense voltage reading has diverged from expected value **BMS Sense Disconnect** BMS sense was connected, but has been disconnected **Shunt or Relay Block** If the host is configured in any way to use a ReadyShunt or ReadyRelay. and one of those blocks is not connected to the Ready Rail (BlockBus), this alarm will be present until the required block is connected. #### Faults **EEPROM Custom Settings Edit** Battery Status LED: Flashing red. Battery SOC LEDs: R-Y-G sequencing. A value has been modified in custom settings memory. The controller will stop charging and indicate a fault condition. After all settings have been modified, the controller must be reset with a reboot control command in LiveView or on the display or by removing and then restoring power to the controller. The new programmed settings will be used after the reset. **Firmware Update Failure** The firmware update was not successfully programmed. The controller will not indicate the full power-up SOC LED sequence of G-Y-R when power to the controller is reset. Instead, the controller will display green, and then stop on yellow. The yellow LED will continue to be lit and the controller will not complete start up or begin charging. Re-try the firmware update. The firmware must be successfully loaded before the controller will start up. **High Heatsink Temperature** Charging Status LED: Flashing red. Battery SOC LEDs: R-Y sequencing. The heatsink temperature has exceeded safe limits and the load is disconnected. The load will automatically reconnect when the heatsink cools to a safe temperature. **High Solar Voltage Disconnect** Charging Status LED: None. Battery SOC LEDs: R-Y-G. If the solar input open-circuit voltage (Voc) exceeds the 185 Volt maximum rating, the array will remain disconnected until the Voc falls to 175V **Solar Battery High Voltage Disconnect (HVD)** Charging Status LED: Flashing red. Battery SOC LEDs: R-G sequencing. This fault is set when battery voltage is above normal operating limits. The controller will disconnect the solar input and set a Solar High Voltage Disconnect fault. This fault is commonly caused by other charging sources in the system, charging the battery above the GenStar MPPT regulation voltage. Recovery occurs at HVD re-connect threshold, and the fault will clear automatically. **Load High Voltage Disconnect (HVD)-disabled by default for lead-acid presets** Charging Status LED: None. Battery SOC LEDs: R-G sequencing. This fault is set when battery voltage is above the Load HVD setpoint if enabled. The controller will disconnect the load output and set a Load High Voltage Disconnect fault. This fault is designed to protect sensitive loads from excessive voltage. Recovery occurs at Load HVD reconnect threshold, if programmed, and the fault will clear automatically. **Battery Over-current** Charging status LED: Flashing red. Battery SOC LEDs: R/Y-G sequencing. While rare, if battery current exceeds approximately 130% of the controller's output current rating, this fault can occur. The fault is generally related to fast, large battery voltage transients (connecting a very heavy or capacitive load like an inverter) that are faster than the controller can regulate, and it shuts off to protect the circuitry. The controller will automatically restart in 10 seconds. **Load Over-current** Charging Status LED: Flashing red. Battery SOC LEDs: R/Y-G sequencing. If the load current exceeds the maximum load current rating, the GenStar MPPT will disconnect the load. The greater the overload the faster the load will be disconnected. A small overload could take a few minutes to disconnect. The GenStar MPPT will attempt to reconnect the load two (2) times. Each attempt is approximately 10 seconds apart. If the overload remains after two (2) attempts, the load will remain disconnected until power is removed and re-applied. **Load Short Circuit** Battery SOC LED sequence: R/G - Y (similar to load overcurrent is R/Y - G). The GenStar MPPT will attempt to reconnect the load two (2) times. Each attempt is approximately 10 seconds apart. If the overload remains after two (2) attempts, the load will remain disconnected until power is removed and re-applied. **Remote Temperature Sensor (RTS)** Charging Status LED: Flashing red. Battery SOC LEDs: R/Y - G/Y sequencing. A bad RTS connection or a severed RTS wire has disconnected the temperature sensor during charging. See Tables 3 and 4 in Section 2.6 for RTS Start-up and Run-time operation and issues. **SOLID CHARGING STATUS LED with SELF-TEST (R-Y-G) Battery SOC FAULTS** Verify that nothing has been mis-wired. If not, the error is likely critical. the table below lists a few common critical faults. See local meter display (Status Menu) for specific error. Contact an authorized Morningstar dealer for support. | **Charging Status LED1** | **Fault** | **Battery SOC LEDs** | | --- | --- | --- | | Solid red | PV FET Short | R-Y-G sequencing | | Solid red | Load FET Short | R-Y-G sequencing | | Solid red | Load FET Open | R-Y-G sequencing | | Solid red | Damaged heatsink temperature sensor | R-Y-G sequencing | | Solid red | Software | R-Y-G sequencing | *1 Solid R Charging Status LED ON with heartbeat blink OFF every five seconds is a critical fault that generally requires service. See local meter display (Status Menu) for specific error.* **STAND-ALONE CHARGING STATUS LED INDICATIONS** | **Charging Status LED** | **Condition** | | --- | --- | | OFF (with heartbeat ON every 5 sec) | Not charging | | Green solid (with heartbeat OFF every 5 sec) | Charging | | Momentary flashing red, then solid red1 | Charger fault2 | *2 See unit meter display (refer to meter map for location) for specific error.*