--- title: "4.8 Commands" slug: "58-commands" updated: 2026-03-06T19:23:28Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/58-commands" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 4.8 Commands Commands can be accessed in the main LiveView dashboard, or in the primary meter screen. Commands are used to control the functions in Sections 4.8.1 - 4.8.6 below. > [!NOTE] > ![A hand pointing to the right, indicating direction or emphasis on an object.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/note hand ISO(2).png) NOTE: > > To use the Commands in LiveView or Morningstar Mobile, MODBUS writes over Ethernet must be enabled. For security purposes, the, "MODBUS writes over Ethernet", enable/disable setting can only be modified on the local meter display. ### 4.8.1 Load Commands Control loads with the following Load control commands. **Load Output Disconnect/ Reconnect** Disconnect and Reconnect the load. Useful for service/maintenance activities or ensuring that all of the loads in the system do not run for a period of time. **Load - LVD Override (XX min)** LVD Override will turn on the load when it has been shut off due to a LVD or LSOCD event. If the battery voltage is above the LVD set-point and/or SOC is above the LSOCD set-point, the load will recover early from an LVD without having to wait for LVR or LSOCR recovery. If the voltage is below the LVD set-point and/or SOC is below the LSOCD set-point, the LVD Override will only recover the load temporarily. It will trigger an LVD Warning alarm and then enter LVD again after the LVD Warning Time (XX min) has expired. ### 4.8.2 Counters Commands Clear-reset counters using commands: **All Resettable Counters** Resets the Resettable A-h and Resettable kW-h counter values to zero. Resettable counters are intended to track mostly in the short-term, for example, accumulations since a battery replacement, or a new load was added to a system. **All Total Counters** Clears the Total A-h and Total kW-h counter values to zero. Total counters are intended to track long-term / lifetime accumulations of a system. ### 4.8.3 Toggle Battery Charger Command Connect or disconnect charging functions using commands: **Manual Equalization** Manually start or stop an equalize charge on a lead-acid battery. This command is only functional for battery charging profiles with Equalization enabled **Battery Charger** Override normal operation and force the battery charger to a disconnected state. The GenStar MPPT will not charge the battery while the charger is in disconnected state. ### 4.8.4 System Commands Activate System commands: **Reboot Control** Software resets the GenStar MPPT. All controller functions, including battery charging and power to the loads, will cease until the reboot is complete. ### 4.8.5 External Source Control (ESC) Commands Control external source signal with commands: - **ESC Enable:** Override the current ESC state and energize the ESC relay while still taking into account the Timing Controls (max runtime and min offtime). Only available for Custom ESC Mode. - **ESC Disable:** Override the current ESC state and de-energize the ESC relay while still taking into account the Timing Controls (min runtime). Only available for Custom ESC Mode. - **Manual Generator Control (Enable/ Disable):** Manually turn on/off the ESC relay while still taking into account the Timing Controls (max runtime and min offtime for Enable; min runtime for Disable). Only available for Manual ESC Mode. - **E-Stop**: De-energize the ESC relay immediately. ### 4.8.6 ReadyRelay Commands ReadyRelays that have been configured for the Command/Schedule function (Section 3.2.7 Relay Function #5) can be toggled ON-OFF with the ReadyRelay Commands. If a Schedule has also been set, the relay can only be controlled when it is not scheduled to be on. Installed Relay Blocks will be listed by positions 1-3 (maximum), and show Relay A and/or B. Position 1 is the first block on the left.