--- title: "5.3 Serial RS-232" slug: "63-serial-rs-232" updated: 2026-03-12T16:00:06Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/63-serial-rs-232" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 5.3 Serial RS-232 5The serial port connection on the GenStar MPPT is a standard 9-pin isolated RS-232 port. See Figure 2-3 (#9) for the port location.The GenStar MPPT communicates through the serial port via the open standard MODBUS protocol. Connect the GenStar MPPT to the serial port for: - Modbus RTU communications - Controller firmware updates with MSLoad firmware utility. LiveView or SD Card firmware updates are recommended for faster uploads. > [!NOTE] > ![A hand pointing to the right, indicating direction or emphasis on an object.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/note hand ISO(2).png) NOTE: > > The RS-232 and EIA-485 ports share hardware. Both ports cannot be used simultaneously. ![Diagram showing a device connected to a computer via a serial cable.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/serial connection between PC and the GenStar MPPT.png) Figure 19. A serial connection between a PC and the GenStar MPPT. **Default Serial Port Settings:** - 9600 Baud rate - 8 data bits - 1 or 2 stop bits - no parity