--- title: "6.3 Battery Charging and Performance Issues" slug: "72-battery-charging-and-performance-issues" updated: 2026-03-12T16:05:37Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/72-battery-charging-and-performance-issues" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 6.3 Battery Charging and Performance Issues | Problem | Solution | | --- | --- | | No LED indications, controller does not appear to be powered | With a multi-meter, check the voltage at the battery terminals on the GenStar MPPT. Battery voltage must be 9 Vdc or greater. If the voltage on the battery terminals of the controller is between 9 and 72 Vdc, and no LEDs are lit, contact your authorized Morningstar dealer for service. If no voltage is measured, check wiring con- nections, fuses, and breakers. | | The GenStar MPPT is not charging the battery. | Check the three (3) battery SOC LEDs. If they are flashing in a sequence, to determine the cause, see Sections 5.6 and 6.1 of this manual. Meter and LiveView will display active faults and alarms. If the LED indications are normal, check the fuses, breakers, and wiring connections in the power source wiring. With a multi-meter, check the array voltage directly at the GenStar MPPT solar input terminals. Input voltage must be greater than battery voltage before charging will begin. | | Controller makes buzzing and humming noises. | No action is required. This is expected due to magnetic resonance and circuit switching. | If troubleshooting does not correct the problem, please refer to Morningstar's Warranty Claim Procedure in Section 7.