--- title: "8.0 Technical Specifications and Certifications" slug: "90technical-specifications" updated: 2026-03-12T16:07:16Z published: 2026-03-12T18:30:24Z canonical: "knowledgebase.morningstarcorp.com/90technical-specifications" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # 8.0 Technical Specifications and Certifications | **Electrical** | **GS-MPPT-60M-200V** | **GS-MPPT-80M-200V** | **GS-MPPT-100M-200V** | | --- | --- | --- | --- | | Maximum Battery Charge Current | 60 Amps | 80 Amps | 100 Amps | | Maximum Input Voltage (Voc) | ALL: 200 Volts | | MPPT Operating Voltage Range | ALL: > battery voltage + 1 Volt; < 180 Volts | | Max. Input Current (Imp/Isc) | 56/60 Amps | 75/80 Amps | 94/100 Amps | | Nominal Operating Voltage | Amps ALL: 12-24-48 VDC | | Battery Voltage Range | ALL: 9-72V (charging); 10-72V (load); Power OFF < 8V | | Maximum Load Current | 30 Amps | 30 Amps | 30 Amps | | Maximum Self-consumption | < 2.4 Watts (12/24V); < 3.2 Watts (48V) | | Grounding Leg | ALL: Negative (pos. ground compatible with array float) | | Real Time Clock (RTC) | ALL: With coin cell (CR-2032) | | Peak Efficiency | ALL: 99% | | Transient Surge Protection | ALL: 4500 Watts/port | | Nominal Maximum Output Power (Watts) | 12, 24, 48 Volts 800, 1600, 3200 | 12, 24, 48 Volts 1064, 2128, 4256 | 12, 24, 48 Volts 1330, 2660, 5320 | | **Mechanical** | | | Dimensions (cm/in) | 36.4/14.3 (H) x 22.2/8.7 (W) x 17.0/6.7 (D) | | Weight (lb/kg) | 14.625 / 6.63 | 15.625 / 7.09 | 16.4375 / 7.46 | | Wire Size Range: | | | Battery and PV input terminals | 10 - 53.5 mm2 / #8 - 1/0 AWG | | Load terminals | 2.5 - 13.3 mm2 / #14 - 6 AWG (EXCEPT fine-stranded #6) | | Equip. grounding terminals | 2.5 - 33.6 mm2 / #14 - 2 AWG | | Battery voltage sense and RTS | 0.25 - 1.0 mm2 / #24 - 16 AWG | | Maximum torque: | | | Battery and PV input terminals | 100 in-lb / 11.3 N-m | | Load terminals | 35 in-lb / 3.9 N-m | | Equip. grounding terminals | 50 in-lb / 5.65 N-m | | Battery voltage sense and RTS | 5 in-lb / 0.565 N-m | | Enclosure | IP20, Type 1 | | **Battery** **Charging** | | | 4-stage Charging | Bulk, Absorption, Float, Equalization | | Temperature compensation | -30mV/12 Volt/ºC | | Coefficient | Shared for Lead-acid presets; disabled by default for Lithium presets) | | Temperature-compensated set-points | (Absorption, Float, Equalize, HVD, HVDR (solar) | | **Communication-Interfaces:** | **GENSTAR MPPT - all models** | | --- | --- | | SD Card | Yes (8 GB included) | | USB-C for data | Yes | | RS-232 Port | Yes | | EIA-485 Port | Yes | | Ethernet/RJ-45 Port | Yes | | Controller Area Network (CAN) | Yes | | Bluetooth Low Power | Yes | | Supported Protocols | Modbus, ModbusIP, HTTP, SNMP v2c, Bluetooth LE | | Datalogging Capacity & Capability | Internal (LiveView): 3 to 4 years daily records; 35,000 to 140,000 events (event frequency can vary greatly) Nearly infinite with 8 GB SD card (datafiles only) | | **Local** **Display:** | | | Digital Meter: | | | Resolution | 128 x 64 | | Viewing Area | 70mm x 40mm | | Display Color Backlight | Blue on white | | Operating Temperature | -20°C to +60°C | | Storage Temperature | -50°C to +80°C | | **Environmental:** | | | Maximum Operating Altitude | 3000 meters | | Ambient Operating Temperature Range | -30°C to +60°C (current may de-rate above 45°C)1 | | Storage Temperature | -50°C to +80°C | | Humidity | 100% n.c. | | Tropicalization | Conformally coated PCBs; | | | Marine-rated terminals | | **Protections:** | | | Reverse night | Battery removal | | Power-up against any active faults | Low temp foldback | | Reverse polarity - array | High temp. foldback | | Solar short-circuit | Solar high voltage | | Solar overload | Load over-current | | High heatsink temperature - current de-rating | Heatsink temperature Limit | | High heatsink temperature - load disconnect | High voltage (solar, battery, load) | | Load short-circuit | Short-circuit | *1 Thermal performance depends on the model and system parameters. See operating manual and Heat Dissipation of GenStar MPPT Controllers Inside Enclosures white paper for further performance characteristic data and information.* #### Efficiency Graphs ![Graph showing GenStar MPPT efficiency versus output power for various voltage levels.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 12.8V.png) ![Graph showing GenStar MPPT efficiency versus output power for 24 volt charging.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 25.6V.png) **NOTES:** *1 80 Vmp curve is very close to 40 Vmp, but most power points are slightly less efficient.* *2 160 Vmp curve is very close to 120 Vmp, but most power points are slightly less efficient.* ![Graph showing GenStar MPPT efficiency versus output power for different voltage settings.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 51.2V.png) ![Graph showing GenStar MPPT efficiency versus output power for different voltage settings.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 51.2V - 2.png) **NOTES:** *1 60 Vmp curve is very close to 52 Vmp, but most power points are slightly less efficient.* *2 120 Vmp curve is very close to 80 Vmp, but most power points are slightly less efficient.* ![Graph showing efficiency versus output power for various voltage settings of a unit.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 12.8batt.png) ![Graph showing efficiency versus output power for an 80A unit at 48V nominal voltage.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 51.2batt.png) ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/9.0technical-specifications-image-pdzv4u9a.png) ![Graph showing efficiency versus output power for a 60A unit at 12V nominal voltage.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 60A unit 12V 12.8batt.png) ![Graph showing efficiency versus output power for a 60A unit at 24V nominal voltage.](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/efficiency vs output at 60A unit 24V 25.6batt.png) ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/9.0technical-specifications-image-fvmyuc9z.png)