--- title: "LiveView Commands Page" slug: "liveview-commands-page" updated: 2025-10-17T18:30:51Z published: 2025-10-17T18:30:51Z canonical: "knowledgebase.morningstarcorp.com/liveview-commands-page" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # LiveView Commands Page The Commands menu provides controls to take action. The type of command cards available/visible on the page will depend on the product and configuration. Access to the Commands page requires the Installer Password. See section [3.6 Installer Access](/docs/liveview-accessing-the-setup-menu#enabling-installer-access-in-liveview) for instructions. ### ReadyEdge Commands Page ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/image(94).png) #### Counters Commands Card Visibility: Always Visible **All Resettable Counters** Clears the Resettable Amp-hour (Ah)and Resettable kilowatt-hour (kWh) counter values to zero. Resettable counters are intended to track short-term energy accumulation. For example, accumulations since a battery replacement, or a new load was added to a system. **All Total Counters** Clears the Total Ah and Total kWh counter values to zero. Total counters are intended to track long-term / lifetime accumulations of a system. #### System Commands Card Visibility: Always Visible **Reboot Control** Software resets the device. All device functions will cease until the reboot is complete. > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) ***NOTE****: In the case of the ReadyEdge, all Connected Products will remain powered and operational. Only the ReadyEdge will reboot.* #### AGS Commands Card Visibility: Visible when Automatic Genstart Enabled & Configured **E-Stop** Stop the generator immediately - override all automatic control. Remains in the stop/off state until E-Stop toggled off. **AGS Enable -** Visible when AGS Mode = AGS Basic or AGS Advanced Override AGS automatic control and force the generator ON immediately (while still taking into account the Timing Controls: max runtime and min off time) **AGS Disable -** Visible when AGS Mode = AGS Basic or AGS Advanced Override AGS automatic control and force the generator OFF immediately (while still taking into account the Timing Controls: max runtime and min off time) **Manual Generator Control (Enable/ Disable)** - Visible when AGS Mode = Manual Manually turn the generator on/off while still taking into account the Timing Controls (max runtime and min offtime for Enable; min runtime for Disable). #### ReadyBlocks Commands Card Visibility: Visible when (1) or more ReadyRelays are configured for Commands/Schedule control **Relay N (custom name)** ReadyRelays that have been assigned the Command/Schedule function can be toggled ON-OFF manually with the slider switch > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) ***NOTE****: If the ReadyRelay also has a schedule assigned, the On/Off command only works when the relay is scheduled to be Off.* ####