--- title: "Step 9B: Connecting Devices Using EIA-485 network" slug: "rs-485-connections" updated: 2025-07-14T15:40:52Z published: 2025-07-14T15:40:52Z canonical: "knowledgebase.morningstarcorp.com/rs-485-connections" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledgebase.morningstarcorp.com/llms.txt > Use this file to discover all available pages before exploring further. # Step 9B: Connecting Devices Using EIA-485 network #### Using EIA-485 versus MeterBus Port for Device Connections For systems with TriStars, the EIA-485 port is the best choice for controller connection. This would be a Modbus over MeterBus connection, and this port can also support many third-party devices. For other ReadyEdge-compatible devices, MeterBus is the best connection. For more than 3 devices, MeterBus with a MeterHub is the best configuration. ### Compatible Charge Controllers and Inverters: #### TriStar: TriStar MPPT 600V TriStar MPPT 150V (60A) Tristar (60A) > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) Note: > > TriStar and TriStar MPPT (30A and 45A models) require EIA-485/RS-232 Adapter (RSC-1) for EIA-485. See the image for 24V/48V Tristar Below. #### Other Devices: For the following devices, connection using the EIA-485 port requires the MRC-1, MeterBus to EIA-485 adapter. SunSaver MPPT ProStar MPPT ProStar SureSine 300 #### EIA-485 Controller Wiring > [!NOTE] > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) **NOTE:** > > All devices on the RS-485 and MODBUS over MeterBus networks must be programmed with a unique MODBUS address. The ReadyEdge should pre-program these addresses, but with third-party devices, you may need to use LiveView to specify these addresses. 1. Connect A, B, and Gnd wires to the EIA-485 network 2. Connect A, B, and Gnd wires to the connected device, or if applicable, the adapter, and then connect the adapter to the device using a serial cable. (See Adapter Manual for specific instructions.) 3. For devices that require additional power, you can connect wires from the 12V out port to the wires from the EIA-485 Port. 4. See connected device manuals for further EIA-485 wiring and installation instructions > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) Note: > > If you connection to the EIA-485 Port is not working, try switching the A and B Wires. Networks requiring power can get power using an external source. The source voltage must be between 8-16 Vdc. For 12-volt systems, the network can be powered directly from the system battery or the 12V power out. For 24, 36, and 48-volt systems, use a DC-DC converter. For Accessory wiring, see the accessory product manual. > ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Note(1).png) **NOTE**: > > Termination resistors may be required to prevent interference from reflected signals. If required, install termination resistors at both ends of the data bus across Data A and Data B to match the characteristic impedance of the communication cables (120Ω for EIA-485 single twisted pair, 100Ω for Category 5 Ethernet). ## **Examples** ### Example of three TriStar 60A or 600V connected to ReadyEdge ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Tristar MPPT (60A or 600V connected to EIA-485.png) Configuration for three Tristar MPPT 60 A Models connected to the ReadyEdge using the EIA-485 Port. The TriStar MPPT (60 A) and TriStar 600V require power to function. Connecting to the 12V Out port is necessary. ### Example of three Tristar 24V/48V connected to the ReadyEdge ![](https://cdn.document360.io/5c3867fe-b3a6-44b5-80c7-4bc7662cc267/Images/Documentation/Tristar (24V or 48V) connected to EIA-485.png) Configuration for three 24V/48V TriStars (TS-45) connected to the ReadyEdge using the EIA-485 Port. If the Tristar were 12V versions, you would be able to power the RSC-1 using the connected Tristar, and the 12V power out port could be used in other ways.