4.5 LED Indications

Prev Next

The GenStar MPPT meter face (see Figure 2) houses one Charging Status LED (left of screen) and a set of three battery State-of-Charge LEDs (beneath screen - horizontal).

Charging Status LED

The Charging Status LED indicates charging status and any existing solar input error conditions. The Status LED is on when charging during the day and off at night. The Status LED will flash red whenever an error condition(s) exists. Table .4..4 lists the Status LED indications.

Status LED Color

Indication

Operating State

None

Off (with heartbeat1)

Night

Green

On Solid (with heartbeat2)

Charging

Red

Flashing

Error

Red

On Solid (with heartbeat2)

Critical Error

1 Heartbeat indication flickers the Status LED on briefly every 5 seconds
2 Heartbeat indication flickers the Status LED off briefly every 5 seconds

NOTES:
  1. R flashing is generally a user addressable fault / error

  2. R charging status LED ON with heartbeat blink OFF every 5 secs is a critical fault that generally requires service. See, "Solid Charging Status LED with Self-test (R-Y-G) SOC Faults", in Section 4.6 Faults and Alarms.

SOC LEDs

The Green, Yellow or Red State-of-Charge LEDs are used for general indications and charging indications.

LED Display Key

G

green

Y

yellow

R

red

Y - R

yellow and red flashing

G / Y

Green and Yellow are both lit at the same time

G / Y - R

Green & Yellow both lit, then red flashing sequentially

G-Y-R

green, yellow and red flashing sequentially

Sequencing LED patterns (faults) repeat until the fault is cleared

General LED Indications

The State of Charge LED's provide the following Start-up and Factory reset indications.

Normal Start-up LED Indication

G for 3 seconds, G-Y-R Flashing, then battery charge status

Start-up Bootload Failed LED Indication

G/Y/R for 3 seconds the STOP on Y

Factory Reset LED Indication

All LED 3 times, then R-Y-G

SOC LED Charging Indications

The Green, Yellow and Red State-of-Charge LEDs are used to indicate the following charging states.

State

SOC LED Indications

Equalize start request

G / Y / R - G / Y / R - G - G

Equalize cancel request

G / Y / R - G / Y / R - R - R

Equalization stage

G flashing (2 per sec)

Absorption stage

G flashing (1 per sec)

Float stage

G flashing (1 per 2 secs)

Battery State-of-Charge (SOC) LED Transitions

During the Bulk Stage, or when the controller is not charging, the Green, Yellow, and Red SOC LEDs will indicate the SOC according to the Battery SOC LED Transition Settings. Battery State-of-Charge (SOC) LED transitions are based on voltage thresholds. When SOC percentage is available from an installed ReadyShunt or ReadyBMS accessory (see Battery State-of-Charge (SOC) Reporting in Section 3.2.7) the SOC LED transitions will be based on SOC percentage.

Factory Default Battery SOC LED Voltage Thresholds

Battery SOC LEDs

Voltage Threshold

Green

battV > 13.3V

Green / Yellow

13.0V < battV <= 13.3V

Yellow

12.65V < battV <= 13.0V

Yellow / Red

battV <= 12.65V

Red

During LVD

Note that voltage threshold State-of-Charge LED displays are only approximate indications of battery charge state, and have variable accuracy during charging and discharging. In addition, the factory default Battery SOC LED indication settings are not appropriate for all battery types and system designs. Therefore, the SOC LED transition settings can be custom programmed to provide a more accurate representation of SOC. The following voltage threshold settings are suggested to better indicate actual SOC.

Suggested Lead-Acid Battery SOC LED Voltage Threshold Settings

Battery SOC LEDs

Voltage Threshold

Green

battV > 13.3V

Green / Yellow

13.0V < battV <= 13.3V

Yellow

12.5V < battV <= 13.00V

Yellow / Red

battV <= 12.50V

Red

During LVD

A hand pointing to the right, indicating direction or emphasis on an object. NOTE:

Thresholds are more representative of SOC during Bulk Charging. Lower settings can be used to better indicate SOC during periods of battery discharge.

Suggested Lithium (LFP) Battery LED Voltage Threshold Settings

Battery SOC LEDs

Voltage Threshold

Green

battV > 13.4V

Green / Yellow

13.25V < battV <= 13.4V

Yellow

13.1V < battV <= 13.25V

Yellow / Red

battV <= 13.1V

Red

During LVD

Factory Default Battery SOC LED SOC Percentages - for use with ReadyBMS or ReadyShunt accessory:

Battery SOC LEDs

Condition

Green

SOC > 80%

Green / Yellow

60% < SOC <= 80%

Yellow

40% < SOC <= 60%

Yellow / Red

SOC <= 40%

Red

LVD or Low SOC Disconnect

Ethernet Jack Indications

Two (2) small LEDs can be found on the Ethernet RJ-45 jack inside the wiring box. These LEDs indicate the LAN/WAN network link and activity status as follows:

Condition

Green LED

Yellow LED

Network Connection OK

ON

OFF

Network Activity

ON

Blinking

Error

OFF

ON