4.8 Commands

Prev Next

Commands can be accessed in the main LiveView dashboard, or in the primary meter screen. Commands are used to control the functions in Sections 4.8.1 - 4.8.6 below.

A hand pointing to the right, indicating direction or emphasis on an object. NOTE:

To use the Commands in LiveView or Morningstar Mobile, MODBUS writes over Ethernet must be enabled. For security purposes, the, "MODBUS writes over Ethernet", enable/disable setting can only be modified on the local meter display.

4.8.1 Load Commands

Control loads with the following Load control commands.

Load Output Disconnect/ Reconnect

Disconnect and Reconnect the load. Useful for service/maintenance activities or ensuring that all of the loads in the system do not run for a period of time.

Load - LVD Override (XX min)

LVD Override will turn on the load when it has been shut off due to a LVD or LSOCD event. If the battery voltage is above the LVD set-point and/or SOC is above the LSOCD set-point, the load will recover early from an LVD without having to wait for LVR or LSOCR recovery. If the voltage is below the LVD set-point and/or SOC is below the LSOCD set-point, the LVD Override will only recover the load temporarily. It will trigger an LVD Warning alarm and then enter LVD again after the LVD Warning Time (XX min) has expired.

4.8.2 Counters Commands

Clear-reset counters using commands:

All Resettable Counters

Resets the Resettable A-h and Resettable kW-h counter values to zero. Resettable counters are intended to track mostly in the short-term, for example, accumulations since a battery replacement, or a new load was added to a system.

All Total Counters

Clears the Total A-h and Total kW-h counter values to zero. Total counters are intended to track long-term / lifetime accumulations of a system.

4.8.3 Toggle Battery Charger Command

Connect or disconnect charging functions using commands:

Manual Equalization

Manually start or stop an equalize charge on a lead-acid battery. This command is only functional for battery charging profiles with Equalization enabled

Battery Charger

Override normal operation and force the battery charger to a disconnected state. The GenStar MPPT will not charge the battery while the charger is in disconnected state.

4.8.4 System Commands

Activate System commands:

Reboot Control

Software resets the GenStar MPPT. All controller functions, including battery charging and power to the loads, will cease until the reboot is complete.

4.8.5 External Source Control (ESC) Commands

Control external source signal with commands:

  • ESC Enable: Override the current ESC state and energize the ESC relay while still taking into account the Timing Controls (max runtime and min offtime). Only available for Custom ESC Mode.

  • ESC Disable: Override the current ESC state and de-energize the ESC relay while still taking into account the Timing Controls (min runtime). Only available for Custom ESC Mode.

  • Manual Generator Control (Enable/ Disable): Manually turn on/off the ESC relay while still taking into account the Timing Controls (max runtime and min offtime for Enable; min runtime for Disable). Only available for Manual ESC Mode.

  • E-Stop: De-energize the ESC relay immediately.

4.8.6 ReadyRelay Commands

ReadyRelays that have been configured for the Command/Schedule function (Section 3.2.7 Relay Function #5) can be toggled ON-OFF with the ReadyRelay Commands.

If a Schedule has also been set, the relay can only be controlled when it is not scheduled to be on.

Installed Relay Blocks will be listed by positions 1-3 (maximum), and show Relay A and/or B. Position 1 is the first block on the left.