EIA-485 is a networking standard for serial communication between multiple devices on a bus. The GenStar MPPT communicates over an EIA-485 network via the open standard MODBUSTM protocol. Use EIA-485 networking to:
Modbus RTU communications
Controller firmware updates with MSLoadTM firmware utility. LiveView or SD Card firmware updates are recommended for faster uploads. (See section 4.10)
Bridge an Ethernet connection through a GenStar MPPT to an EIA-485 network
Each device in the EIA-485 network must have a unique MODBUSTM Address. Change the GenStar MPPT Modbus address from the device Modbus address as required for each device.
A bridged Ethernet connection through a GenStar MPPT to an EIA-485 network can provide an Ethernet connection through a Genstar MPPT to a EIA-485 network. The Genstar unit used to bridge the Ethernet connection to the EIA-485 network must have, "Bridging", enabled in either its local meter or in LiveView.
EIA-485 WIRING
The EIA-485 port has three (3) connections: GND, Data A, Data B. Data A & B are differentially driven data lines that carry the network data. The GenStar MPPT supplies isolated power to the EIA-485 network, eliminating the need for an external bus power source in many cases.
WARNING:
Before wiring, verify that all system breakers and disconnect switches are in the OPEN/DISCONNECTED position, and that all fuses are removed from their holders.
Connections:
From left to right, connect GND, Data A, Data B wires to the GenStar EIA-485 terminals.
Connect GND, Data A and Data B wires (with the same order and orientation as on the GenStar EIA-485 terminals) to a desired bus-connected controller, e.g., another GenStar.
If a desired bus-connected (EIA-485 compatible) controller is not a GenStar, a voltage supply will need to be provided to the bus at the connected controller.
Networks requiring power can be supplied by an external source. The source voltage must be between 8-16 Vdc. For 12 Volt systems, the network can be powered directly from the system battery. For 24, 36, and 48 Volt systems, use a DC-DC converter.
CAUTION: EQUIPMENT DAMAGE
Tapping power off of individual batteries in a series string of batteries can cause a voltage imbalance. Damage to the batteries may result. Always use a DC-DC converter to power the EIA-485 network if the nominal system voltage is greater than 12 volts.
NOTE:
The RS-232 and EIA-485 ports share hardware. Both ports cannot be used simultaneously.
NOTE:
Termination resistors may be required to prevent interference from reflected signals. If required, install termination resistors at both ends of the data bus across Data A and Data B to match the characteristic impedances of the communication cables (1200 for RS-485 single twisted pair, 1000 for Category 5 Ethernet).
For more information on EIA-485 networking, refer to the, "Morningstar Communications Document", on the Morningstar website at: