See 1.2 Product Features to reference LED type and location
After the ReadyEdge has been installed, the unit with connect with Ethernet and LiveView after connecting the power supply. See Power In Battery Connections for more information. If there are no faults or alarms, on start-up the status LED will flash green once, and then all LEDs will light green simultaneously for three seconds. Next, the ReadyEdge will automatically begin searching for valid Morningstar Devices.
Major LED Indications | |
|---|---|
Status LED (Top LED) | |
Green-solid | No Local or Remote faults |
Green-flashing | Recovery Firmware Update |
Red-solid (heartbeat) | Active ReadyEdge Fault |
Red-flashing | Active Remote (Connected Morningstar Device) Fault |
Bluetooth LED | |
Unlit | OFF |
Blue-solid | Bluetooth Enabled |
IOT Connectivity | |
Unlit | Not Connected |
Green-solid | Cloud Connected |
Ethernet Connectivity | |
Ethernet power and network activity | |
Read Only Mode* | |
Green-solid | Read-Only Mode OFF - Ethernet writes enabled |
Red-solid | Read-Only Mode ON - Ethernet writes disabled |
NOTE: The ReadyEdge is shipped with Read Only Mode off, indicated by a green light on the 4th LED (unlock icon). Ready Only mode must remain disabled to configure the ReadyEdge in LiveView. Read Only Mode is controlled by DIP Switch 1.
Proceed to 3.0 Configuration to adjust settings and finish setup.